840 research outputs found

    First Steps Toward Change in Teacher Preparation for Elementary Science

    Get PDF
    Unless introductory undergraduate science classes for prospective elementary teachers actively incorporate the philosophy of inquiry-based learning called for in K-l2 science education refom little will change in elementary science education. Thus, at James Madison University, we have developed a new integrated science core curriculum called Understanding our World [1]. This course sequence was not only designed to fulfill general education science requirements. but also to focus on content areas our students will need to know as teachers. The objectives of these courses are based on the National Science Education Standards and Virginia’s Science Standards of Learning, including earth and space science, chemistry, physics, life sciences, and environmental science [2,3]. As an integrated package, this course sequence addresses basic science content, calculation skills, the philosophy and history of science, the process of how science is done, the role of science in society, and applications of computers and technology in science. Keeping in mind that students tend to teach in the same way they were taught, Understanding our World core classes embrace the concepts associated with reform in elementary math and science

    Genomic profile of a squamous cell carcinoma Ex pleomorphic adenoma compared to a head and neck squamous cell carcinoma

    Get PDF
    [No abstract available]sem informação843393397FAPESP - FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO2011/23204-5; 2011/23366-

    Development of a very low-noise cryogenic pre-amplifier for large-area SiPM devices

    Full text link
    Silicon Photomultipliers (SiPMs) are an excellent candidate for the development of large-area light sensors. Large SiPM-based detectors require low-noise pre-amplifiers to maximize the signal coupling between the sensor and the readout electronics. This article reports on the development of a low-noise transimpedance amplifier sensitive to single-photon signals at cryogenic temperature. The amplifier is used to readout a 1 cm2^{2} SiPM with a signal to noise ratio in excess of 40

    Atomic Hole Doping of Graphene

    Full text link
    Graphene is an excellent candidate for the next generation of electronic materials due to the strict two-dimensionality of its electronic structure as well as the extremely high carrier mobility. A prerequisite for the development of graphene based electronics is the reliable control of the type and density of the charge carriers by external (gate) and internal (doping) means. While gating has been successfully demonstrated for graphene flakes and epitaxial graphene on silicon carbide, the development of reliable chemical doping methods turns out to be a real challenge. In particular hole doping is an unsolved issue. So far it has only been achieved with reactive molecular adsorbates, which are largely incompatible with any device technology. Here we show by angle-resolved photoemission spectroscopy that atomic doping of an epitaxial graphene layer on a silicon carbide substrate with bismuth, antimony or gold presents effective means of p-type doping. Not only is the atomic doping the method of choice for the internal control of the carrier density. In combination with the intrinsic n-type character of epitaxial graphene on SiC, the charge carriers can be tuned from electrons to holes, without affecting the conical band structure

    Measurement of airborne fission products in Chapel Hill, NC, USA from the Fukushima Dai-ichi reactor accident

    Get PDF
    We present measurements of airborne fission products in Chapel Hill, NC, USA, from 62 days following the March 11, 2011, accident at the Fukushima Dai-ichi nuclear power plant. Airborne particle samples were collected daily in air filters and radio-assayed with two high-purity germanium (HPGe) detectors. The fission products I-131 and Cs-137 were measured with maximum activities of 4.2 +/- 0.6 mBq/m^3 and 0.42 +/- 0.07 mBq/m^3 respectively. Additional activity from I-131, I-132, Cs-134, Cs-136, Cs-137 and Te-132 were measured in the same air filters using a low-background HPGe detector at the Kimballton Underground Research Facility (KURF).Comment: 10 pages, 4 figure

    Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision

    Get PDF
    We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 x 10^{12} decays. Two different stopping target configurations were employed in independent data-taking periods. The combined results give tau_{mu^+}(MuLan) = 2196980.3(2.2) ps, more than 15 times as precise as any previous experiment. The muon lifetime gives the most precise value for the Fermi constant: G_F(MuLan) = 1.1663788 (7) x 10^-5 GeV^-2 (0.6 ppm). It is also used to extract the mu^-p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g_P.Comment: Accepted for publication in Phys. Rev. Let

    Improved Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant

    Full text link
    The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau_mu = 2.197013(24) us, is in excellent agreement with the previous world average. The new world average tau_mu = 2.197019(21) us determines the Fermi constant G_F = 1.166371(6) x 10^-5 GeV^-2 (5 ppm). Additionally, the precision measurement of the positive muon lifetime is needed to determine the nucleon pseudoscalar coupling g_P.Comment: As published version (PRL, July 2007

    The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76

    Full text link
    The {\sc Majorana} collaboration is searching for neutrinoless double beta decay using 76^{76}Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining sensitivities for neutrino masses in the inverted hierarchy region, 155015 - 50 meV, will require large, tonne-scale detectors with extremely low backgrounds, at the level of \sim1 count/t-y or lower in the region of the signal. The {\sc Majorana} collaboration, with funding support from DOE Office of Nuclear Physics and NSF Particle Astrophysics, is constructing the {\sc Demonstrator}, an array consisting of 40 kg of p-type point-contact high-purity germanium (HPGe) detectors, of which \sim30 kg will be enriched to 87% in 76^{76}Ge. The {\sc Demonstrator} is being constructed in a clean room laboratory facility at the 4850' level (4300 m.w.e.) of the Sanford Underground Research Facility (SURF) in Lead, SD. It utilizes a compact graded shield approach with the inner portion consisting of ultra-clean Cu that is being electroformed and machined underground. The primary aim of the {\sc Demonstrator} is to show the feasibility of a future tonne-scale measurement in terms of backgrounds and scalability.Comment: Proceedings for the MEDEX 2013 Conferenc

    Contamination Control and Assay Results for the Majorana Demonstrator Ultra Clean Components

    Full text link
    The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.Comment: Proceedings of Low Radioactivity Techniques (LRT May 2017, Seoul
    corecore